= Introduction =
+
__FORCETOC__
  
This page provides the information about the PL initialization signals: PROGRAM_B, INIT_B, and DONE
+
<section begin=PL/>
  
= PL Logic =
+
==PL initialization signals ==
 +
This page provides information about the Programmable Logic (PL) initialization signals: PROGRAM_B, INIT_B, and DONE.
  
 
Please refer to [https://www.xilinx.com/support/documentation/user_guides/ug585-Zynq-7000-TRM.pdf#page=218 Zynq Technical Reference Manual UG-585] for more information about usage and configuration of initialization circuit and signals.
 
Please refer to [https://www.xilinx.com/support/documentation/user_guides/ug585-Zynq-7000-TRM.pdf#page=218 Zynq Technical Reference Manual UG-585] for more information about usage and configuration of initialization circuit and signals.
  
As written in UG-585 ''the Table 6-24: PL Initialization Signals'', the user can initialize the PL using the signals.
+
As described in ''Table 6-24: PL Initialization Signals'' of ''Zynq-7000 SoC Technical Reference Manual (UG585)'', the user can initialize the PL using these signals.
  
 
BORA, BORAX, and BORALite SOM are configured in the following way:
 
BORA, BORAX, and BORALite SOM are configured in the following way:
 
 
* PROGRAM_B has an internal 10kΩ pull-up to VCCO_0 as indicated on Xilinx [https://www.xilinx.com/support/answers/56272.html AR#56272]
 
* PROGRAM_B has an internal 10kΩ pull-up to VCCO_0 as indicated on Xilinx [https://www.xilinx.com/support/answers/56272.html AR#56272]
 
* INIT_B has no pull-up/down
 
* INIT_B has no pull-up/down
* DONE has no pull-up/down. It does not require and external pull-up or pull-down but can be used for connecting a user led for a configuration completed indication (see for example [https://mirror.dave.eu/bora/hw/BoraXEVB/S-EVBBX0000C0R-1.6.1_color.pdf#page=4 BoraXEVB schematics]).
+
* DONE has no pull-up/down. It does not require any external pull-up or pull-down but can be used for connecting a user led for a configuration completed indication (see for example [https://mirror.dave.eu/bora/hw/BoraXEVB/S-EVBBX0000C0R-1.6.1_color.pdf#page=4 BoraXEVB schematics]).
  
= External pull-ups =
+
=== External pull-ups ===
* PROGRAM_B: for a stronger pull-up, as indicated in the UG-585, place an external pull-up to a 3.3V controlled power domain in order to put it in parallel with the internal 10kΩ pull-up.
+
* PROGRAM_B: UG-585 indicates to use a 4.7kΩ pull-up resistor for this signal. This value was not known when the Xilinx Zynq 7000 family was released. Nevertheless, to date, no issues have been reported although this pull-up is a little bit weaker. In any case, an external pull-up to a 3.3V controlled power domain can be put in parallel with the internal 10kΩ resistor to get a stronger pull-up. For more details, please contact [mailto:helpdesk@dave.eu the technical support].
 
* INIT_B: for using this signal as ''PL initializing signal Low-to-High transition'', place an external pull-up to a 3.3V controlled power domain.
 
* INIT_B: for using this signal as ''PL initializing signal Low-to-High transition'', place an external pull-up to a 3.3V controlled power domain.
"3.3V controlled power domain" means that this rail has to designed in order to meet the power sequences described [[Power (Bora/BoraLite)|here]]. For this purpose, the BOARD_PGOOD signal can be used as illustrated in the following example:
 
 
== 3V3 on Carrier board ==
 
 
'''Attention''': the 3V3 Carrier power domain, has to be driven and controlled via BOARD_PGOOD signal as indicated on [[Power_(Bora/BoraLite)| Power page]]
 
 
A controlled switch can be placed in the Carrier board following the schematics example here below:
 
 
[[File:BORA_BOARD_PGOOD_3V3.png|center|thumb|3V3 controlled via BOARD_PGOOD]]
 
  
Please, take into account that a similar internal switch (from 3V3_VIN to 3V3 used by SOM's internal circuit) has a 654 us switch delay.
+
<section end=PL/>

Latest revision as of 15:18, 11 January 2024

Info Box
Bora5-small.jpg Applies to Bora
BORA Xpress.png Applies to BORA Xpress
BORALite-TOP.png Applies to BORA Lite



PL initialization signals[edit | edit source]

This page provides information about the Programmable Logic (PL) initialization signals: PROGRAM_B, INIT_B, and DONE.

Please refer to Zynq Technical Reference Manual UG-585 for more information about usage and configuration of initialization circuit and signals.

As described in Table 6-24: PL Initialization Signals of Zynq-7000 SoC Technical Reference Manual (UG585), the user can initialize the PL using these signals.

BORA, BORAX, and BORALite SOM are configured in the following way:

  • PROGRAM_B has an internal 10kΩ pull-up to VCCO_0 as indicated on Xilinx AR#56272
  • INIT_B has no pull-up/down
  • DONE has no pull-up/down. It does not require any external pull-up or pull-down but can be used for connecting a user led for a configuration completed indication (see for example BoraXEVB schematics).

External pull-ups[edit | edit source]

  • PROGRAM_B: UG-585 indicates to use a 4.7kΩ pull-up resistor for this signal. This value was not known when the Xilinx Zynq 7000 family was released. Nevertheless, to date, no issues have been reported although this pull-up is a little bit weaker. In any case, an external pull-up to a 3.3V controlled power domain can be put in parallel with the internal 10kΩ resistor to get a stronger pull-up. For more details, please contact the technical support.
  • INIT_B: for using this signal as PL initializing signal Low-to-High transition, place an external pull-up to a 3.3V controlled power domain.