Changes

Jump to: navigation, search
The automatic test procedure
**For each stream, it computes the CRC32 for every received frame in real-time. In case the computed value matches Ref_CRC, the counter of valid frames is incremented. Otherwise, the frame of the corrupted frames is increased.
*After a while, the master test module stops the video test and verify the counters. If all of the transmitted frames are good, the test is passed.
===Future work===
The acquisition of the LVDS/HDMI video streams can be optimized by using the SerDes modules provided by the Zynq SOC. This implementation would allow avoiding the use of the external deserializers.
4,650
edits