Difference between revisions of "Thermal tests and measurements (SBCX)"

From DAVE Developer's Wiki
Jump to: navigation, search
(Test beds)
Line 26: Line 26:
 
*SBCX equipped iMX6 Dual Lite processor (maximum frequency = TBD) and 1GB SDRAM
 
*SBCX equipped iMX6 Dual Lite processor (maximum frequency = TBD) and 1GB SDRAM
 
*LCD TBD.
 
*LCD TBD.
 +
 
Settings common to all test beds:
 
Settings common to all test beds:
 
*SBCX supply voltage: 12V
 
*SBCX supply voltage: 12V
 
*Linux governor: TBD
 
*Linux governor: TBD
 
*LCD backlight intensity: 100%
 
*LCD backlight intensity: 100%
 +
*still air flow
 
*software load [1]
 
*software load [1]
 
** TBD.
 
** TBD.
  
* test bed #1
+
 
 +
===Test bed #1===
 
**Tamb = TBD °C
 
**Tamb = TBD °C
**system layout - SBCX
+
**system layout
 +
***SBCX and LCD lie on a table horizontally (see also the following picture)
 
tbd inserire foto
 
tbd inserire foto
* test bed #2:
+
 
 +
===Test bed #2===
 
**Tamb = TBD °C
 
**Tamb = TBD °C
**system layout - SBCX
+
**system layout
 +
***SBCX and LCD are enclosed in a metal box that lies on a table horizontally (see also the following picture)
 +
***iMX6 processor is thermally coupled with an heat sink (TBD) through TBD
 
tbd inserire foto
 
tbd inserire foto
* test bed #3:
+
 
 +
===Test bed #3===
 
**Tamb = TBD °C
 
**Tamb = TBD °C
**system layout - SBCX
+
**system layout
 +
***SBCX and LCD are enclosed in a metal box that is positioned vertically (see also the following picture)
 +
***iMX6 processor is thermally coupled with an heat sink (TBD) through TBD
 
tbd inserire foto
 
tbd inserire foto
* test bed #4:
+
 
 +
===Test bed #4===
 
**Tamb = TBD °C
 
**Tamb = TBD °C
**system layout - SBCX
+
**system layout
 +
***SBCX and LCD are enclosed in a metal box that lies on a table horizontally (see also the following picture)
 +
***iMX6 processor is thermally coupled with an aluminium heat pipe (TBD) through TBD
 +
***in turn, heat pipe is thermally coupled with the box through TBD
 
tbd inserire foto
 
tbd inserire foto
* test bed #5:
+
 
 +
===Test bed #5===
 
**Tamb = TBD °C
 
**Tamb = TBD °C
**system layout - SBCX
+
**system layout
 +
***SBCX and LCD are enclosed in a metal box that is positioned vertically (see also the following picture)
 +
***iMX6 processor is thermally coupled with an aluminium heat pipe (TBD) through TBD
 +
***in turn, heat pipe is thermally coupled with the box through TBD
 
tbd inserire foto
 
tbd inserire foto
 +
 
==Results==
 
==Results==
 
*test bed #1
 
*test bed #1

Revision as of 17:22, 10 October 2016

WorkInProgress.gif

Info Box
SBC-AXEL-02.png Applies to SBC AXEL


History[edit | edit source]

Version Date Notes
First public release

Introduction[edit | edit source]

This document describes the tests that have been performed on SBCX board to characterize thermal behavior of some configurations. The results here presented can be used by integrators building systems upon SBCX board as a basis for comparison. In fact, as stated in the SBCX's Hardware Manual, systems integrators have to perform thermal analysis on the application's definitive configuration that generally differs significantly with respect to the use cases here described, in terms of both hardware and software.

Test beds[edit | edit source]

Five different test beds have been considered. From the electronics point of view, all of them are based on the following parts:

  • SBCX equipped iMX6 Dual Lite processor (maximum frequency = TBD) and 1GB SDRAM
  • LCD TBD.

Settings common to all test beds:

  • SBCX supply voltage: 12V
  • Linux governor: TBD
  • LCD backlight intensity: 100%
  • still air flow
  • software load [1]
    • TBD.


Test bed #1[edit | edit source]

    • Tamb = TBD °C
    • system layout
      • SBCX and LCD lie on a table horizontally (see also the following picture)

tbd inserire foto

Test bed #2[edit | edit source]

    • Tamb = TBD °C
    • system layout
      • SBCX and LCD are enclosed in a metal box that lies on a table horizontally (see also the following picture)
      • iMX6 processor is thermally coupled with an heat sink (TBD) through TBD

tbd inserire foto

Test bed #3[edit | edit source]

    • Tamb = TBD °C
    • system layout
      • SBCX and LCD are enclosed in a metal box that is positioned vertically (see also the following picture)
      • iMX6 processor is thermally coupled with an heat sink (TBD) through TBD

tbd inserire foto

Test bed #4[edit | edit source]

    • Tamb = TBD °C
    • system layout
      • SBCX and LCD are enclosed in a metal box that lies on a table horizontally (see also the following picture)
      • iMX6 processor is thermally coupled with an aluminium heat pipe (TBD) through TBD
      • in turn, heat pipe is thermally coupled with the box through TBD

tbd inserire foto

Test bed #5[edit | edit source]

    • Tamb = TBD °C
    • system layout
      • SBCX and LCD are enclosed in a metal box that is positioned vertically (see also the following picture)
      • iMX6 processor is thermally coupled with an aluminium heat pipe (TBD) through TBD
      • in turn, heat pipe is thermally coupled with the box through TBD

tbd inserire foto

Results[edit | edit source]

  • test bed #1
    • overall power consumption (steady state): TBD [1]
    • SOM power consumption (steady state): TBD [1]
    • Tj = TBD °C
    • ∆T = Tj - Tamb = TBD °C
  • test bed #2
    • overall power consumption (steady state): TBD [1]
    • SOM power consumption (steady state): TBD [1]
    • Tj = TBD °C
    • ∆T = Tj - Tamb = TBD °C
  • test bed #3
    • overall power consumption (steady state): TBD [1]
    • SOM power consumption (steady state): TBD [1]
    • Tj = TBD °C
    • ∆T = Tj - Tamb = TBD °C
  • test bed #4
    • overall power consumption (steady state): TBD [1]
    • SOM power consumption (steady state): TBD [1]
    • Tj = TBD °C
    • ∆T = Tj - Tamb = TBD °C
  • test bed #5
    • overall power consumption (steady state): TBD [1]
    • SOM power consumption (steady state): TBD [1]
    • Tj = TBD °C
    • ∆T = Tj - Tamb = TBD °C


[1] Even if the software load is the same for all of the test beds, overall and SOM power consumptions differ accross the test beds. This is due to the silicon static power consumption that is a function of the temperature itself.

Useful links[edit | edit source]