Changes

Jump to: navigation, search
no edit summary
===Prerequisites===
* LA-3500 Power Debug USB3 or LA-7705 Power Debug Ethernet or LA-7699 PowerDebug II* LA-7843 JTAG Debugger for Cortex-A/-R* LA-7960X License for Multicore Debugging* TRACE32 PowerView for ARM (Release: Feb 2013, Software Version: R.2013.02.000045901)* Optional: LA-7970X Trace License for ARM (Debug Cable)
For a general introduction to debug features provided by TRACE32 tools, please refer to:
“Debugger * ''Debugger Basics – Training” Training'' manual (<code>training_debugger.pdf</code>)“Training * ''Training HLL Debugging” Debugging'' manual (<code>training_hll.pdf</code>)
===TRACE32 configuration===
In AMP configuration, each core runs a unique code, already fixed at compile time. The CPU interoperates with other processing units, exchanging data through dedicated channels (for example, shared memory buffers or peripheral units). Lauterbach supports these architectures with different TRACE32 instances, each one connected to a single core, in “core view” ''core view'' configuration where debug focus is on single processor.
However, as the cores do not work independently but perform the application task together and in parallel, it is possible to start and stop all the cores simultaneously. This is the only way to test the interaction between the cores and to monitor and control the entire application. Moreover, as each core run a separate part of the application, the majority of the symbol and debug information is assigned exclusively to the corresponding core.
 In the following paragraphs, the basic TRACE32 multicore configuration for a single device will be introduced. For more details, please refer to “ICD ''ICD Debugger User's Guide” Guide'' (<code>debugger_user.pdf</code>).
====Multicore configuration====
For the configuration of TRACE32 application, reference scripts are provided from Lauterbach. The first GUI must be started manually and must register itself to share a common JTAG handler with other TRACE32 applications. This is done setting the option <code>CORE= </code> in the configuration file (default file name: <code>config.t32</code>).<pre>
PBI= ; within config file of first core
USB
CORE=1
</pre>
or:
<pre>
PBI= ; within config file of first core
NET
PACKLEN=1024
CORE=1
</pre>
Nevertheless, the setting to define which core is addressed, actually is done later on.
====Multicore synchronization====
To use the start/stop synchronization between different core debuggers, the <code>INTERCOM </code> port settings are necessary. This is done assigning predefined port numbers in the configuration file to each TRACE32 application (option <code>PORT=</code>).<pre>
IC=NETASSIST ; within config file of first core
PORT=20001
IC=NETASSIST ; within config file of second core
PORT=20002
</pre>
===Startup scripts===
In order to use a generic configuration file for each TRACE32 instance, there is the possibility to use just one generic template file for all cores. The particular settings are passed as parameter. This is shown in the reference script:
<pre>
amp_start_core0.bat
</pre>
which refers to the configuration file:
<pre>
amp_config.t32
</pre>
The batch file starts automatically this startup script:
<pre>
amp_demo.cmm
</pre>
After booting the first TRACE32 GUI, the second GUI will be started automatically by the startup script. See the reference script:
<pre>
amp_demo_start_core1.cmm
</pre>
For more details about PRACTICE batch language, please refer to:
“Training PRACTICE” * ''Training PRACTICE'' manual (<code>training_practice.pdf</code>)“PRACTICE * ''PRACTICE Script Language User´s Guide” Guide'' (<code>practice_user.pdf</code>)“PRACTICE * ''PRACTICE Script Language Reference Guide” Guide'' (<code>practice_ref.pdf</code>)
====PRACTICE macros for multiple TRACE32====
The startup script, started automatically at the first TRACE32 application, is fully able to configure the whole debug system, providing PRACTICE commands both to the current instance of TRACE32 application, and to the second instance. It’s also possible to deliver the same PRACTICE command to both instances with a single command line. The command redirection is possible using the INTERCOM feature. Typically some PRACTICE macros can be defined for this purpose.