Pinout (BORAXpress)

From DAVE Developer's Wiki
Revision as of 15:59, 26 November 2018 by U0001 (talk | contribs) (J1 odd pins (1 to 139))

Jump to: navigation, search
Info Box
BORA Xpress.png Applies to BORA Xpress

Introduction[edit | edit source]

This chapter contains the pinout description of the BORA Xpress module, grouped in six tables (two – odd and even pins – for each connector) that report the pin mapping of the three 140-pin BORA Xpress connectors. Each row in the pinout tables contains the following information:

  • Pin: reference to the connector pin
  • Pin Name: pin (signal) name on the BORA Xpress connectors
  • Internal connections: connections to the BORA Xpress components
    • CPU.<x> : pin connected to CPU (processing system) pad named <x>
    • FPGA.<x>: pin connected to FPGA (programmable logic) pad named <x>
    • CAN.<x> : pin connected to the CAN transceiver
    • LAN.<x> : pin connected to the LAN PHY
    • USB.<x> : pin connected to the USB transceiver
    • NAND.<x>: pin connected to the flash NAND
    • NOR.<x>: pin connected to the flash NOR
    • SV.<x>: pin connected to voltage supervisor
    • MTR: pin connected to voltage monitors
  • Ball/pin #: Component ball/pin number connected to signal
  • Supply Group: Power Supply Group
  • Type: pin type
    • I = Input
    • O = Output
    • D = Differential
    • Z = High impedance
    • S = Power supply voltage
    • G = Ground
    • A = Analog signal
  • Voltage: I/O voltage levels

J1 odd pins (1 to 139)[edit | edit source]

Pin Pin Name Internal Connections Ball/pin # Supply Group Type Voltage Note
J1.1 DGND DGND - - G - Digital ground
J1.3 IO_25_VRP_35 FPGA.IO_25_35/IO_25_VRP_35 H5 Bank 35 I/O User defined Optional on-board pull-down
J1.5 IO_L23P_T3_35 FPGA.IO_L10P_T1_AD11P_35 F2 Bank 35 I/O User defined
J1.7 IO_L23N_T3_35 FPGA.IO_L23N_T3_35 F1 Bank 35 I/O User defined
J1.9 IO_L21P_T3_DQS_AD14P_35 FPGA.IO_L21P_T3_DQS_AD14P_35 E4 Bank 35 I/O User defined
J1.11 IO_L21N_T3_DQS_AD14N_35 FPGA.IO_L21N_T3_DQS_AD14N_35 E3 Bank 35 I/O User defined
J1.13 DGND DGND - - - - Digital ground
J1.15 IO_L19P_T3_35 FPGA.IO_L19P_T3_35 H4 Bank 35 I/O User defined
J1.17 IO_L19N_T3_VREF_35 FPGA.IO_L19N_T3_VREF_35 H3 Bank 35 I/O User defined
J1.19 DGND DGND - - G - Digital ground
J1.21 IO_L17P_T2_AD5P_35 FPGA.IO_L17P_T2_AD5P_35 E2 Bank 35 I/O User defined
J1.23 IO_L17N_T2_AD5N_35 FPGA.IO_L17N_T2_AD5N_35 D2 Bank 35 I/O User defined
J1.25 IO_L15P_T2_DQS_AD12P_35 FPGA.IO_L15P_T2_DQS_AD12P_35 A2 Bank 35 I/O User defined
J1.27 IO_L15N_T2_DQS_AD12N_35 FPGA.IO_L15N_T2_DQS_AD12N_35 A1 Bank 35 I/O User defined
J1.29 DGND DGND - - G - Digital ground
J1.31 IO_L13P_T2_MRCC_35 FPGA.IO_L13P_T2_MRCC_35 B4 Bank 35 I/O User defined
J1.33 IO_L13N_T2_MRCC_35 FPGA.IO_L13N_T2_MRCC_35 B3 Bank 35 I/O User defined
J1.35 DGND DGND - - G - Digital ground
J1.37 IO_L11P_T1_SRCC_35 FPGA.IO_L11P_T1_SRCC_35 C6 Bank 35 I/O User defined
J1.39 IO_L11N_T1_SRCC_35 FPGA.IO_L11N_T1_SRCC_35 C5 Bank 35 I/O User defined
J1.41 IO_L9P_T1_DQS_AD3P_35 FPGA.IO_L9P_T1_DQS_AD3P_35 A7 Bank 35 I/O User defined
J1.43 IO_L9N_T1_DQS_AD3N_35 FPGA.IO_L9N_T1_DQS_AD3N_35 A6 Bank 35 I/O User defined
J1.45 IO_L7P_T1_AD2P_35 FPGA.IO_L7P_T1_AD2P_35 C8 Bank 35 I/O User defined
J1.47 IO_L7N_T1_AD2N_35 FPGA.IO_L7N_T1_AD2N_35 B8 Bank 35 I/O User defined
J1.49 DGND DGND - - G - Digital ground
J1.51 IO_L5P_T0_AD9P_35 FPGA.IO_L5P_T0_AD9P_35 F5 Bank 35 I/O User defined
J1.53 IO_L5N_T0_AD9N_35 FPGA.IO_L5N_T0_AD9N_35 E5 Bank 35 I/O User defined
J1.55 IO_L3P_T0_DQS_AD1P_35 FPGA.IO_L3P_T0_DQS_AD1P_35 E8 Bank 35 I/O User defined
J1.57 IO_L3N_T0_DQS_AD1N_35 FPGA.IO_L3N_T0_DQS_AD1N_35 D8 Bank 35 I/O User defined
J1.59 DGND DGND - - G - Digital ground
J1.61 IO_L1P_T0_AD0P_35 FPGA.IO_L1P_T0_AD0P_35 F7 Bank 35 I/O User defined
J1.63 IO_L1N_T0_AD0N_35 FPGA.IO_L1N_T0_AD0N_35 E7 Bank 35 I/O User defined
J1.65 DGND DGND - - G - Digital ground
J1.67 VDDIO_BANK35 S
J1.69 XADC_AGND G XADC analog ground (internally connected to DGND)
J1.71 XADC_AGND G XADC analog ground (internally connected to DGND)
J1.73 PS_MIO45_501 CPU.PS_MIO45_501 B14 Bank 501 I/O 1.8V
J1.75 PS_MIO44_501 CPU.PS_MIO44_501 E10 Bank 501 I/O 1.8V
J1.77 PS_MIO43_501 CPU.PS_MIO43_501 B12 Bank 501 I/O 1.8V
J1.79 PS_MIO42_501 CPU.PS_MIO42_501 D15 Bank 501 I/O 1.8V
J1.81 PS_MIO41_501 CPU.PS_MIO41_501 C15 Bank 501 I/O 1.8V
J1.83 DGND DGND - - G - Digital ground
J1.85 PS_MIO40_501 CPU.PS_MIO40_501 E9 Bank 501 I/O 1.8V
J1.87 ETH_MDIO CPU.PS_MIO53_501 C11 Bank 501 I/O 1.8V 1kOhm pull-up
J1.89 ETH_MDC CPU.PS_MIO51_501 D13 Bank 501 I/O 1.8V
J1.91 ETH_LED1 LAN.LED1/PME_N1 17 - 1.8V 10kOhm pull-up
J1.93 ETH_LED2 LAN.LED2 15 - 1.8V 10kOhm pull-up
J1.95 DGND DGND - - G - Digital ground
J1.97 ETH_TXRX1_M LAN.TXRXM_B 6 D
J1.99 ETH_TXRX1_P LAN.TXRXP_B 5 D
J1.101 DGND DGND - - G - Digital ground
J1.103 ETH_TXRX0_M LAN.ETH_TXRX0_M 3 D
J1.105 ETH_TXRX0_P LAN.ETH_TXRX0_P 2 D
J1.107 DVDDH LAN.DVDDH 16
34
40
1.8V
J1.109 RFU - - - - - Reserved fo future use. Must be left floating.
J1.111 USBOTG_CPEN USB.CPEN 7 3.3V
J1.113 OTG_VBUS USB.OTG_VBUS 2
J1.115 OTG_ID USB.ID 1
J1.117 DGND DGND - - G - Digital ground
J1.119 SPI0_DQ3/MODE0/NAND_IO0 CPU.PS_MIO5_500
NOR flash
NAND flash
CPU.A20 Bank 500 I/O 3.3V This signal is pulled up or down by 20kOhm resistor to select proper bootstrap configuration.

Default configuration: pull-up (BOOT_MODE[0]=1)
J1.121 SPI0_DQ2/MODE2/NAND_IO2 CPU.PS_MIO4_500
NOR flash
NAND flash
CPU.E19 Bank 500 I/O 3.3V This signal is pulled up or down by 20kOhm resistor to select proper bootstrap configuration.

Default configuration: pull-down (BOOT_MODE[2]=0)
J1.123 SPI0_DQ1/MODE1/NAND_WE CPU.PS_MIO3_500
NOR flash
NAND flash
CPU.F17 Bank 500 I/O 3.3V This signal is pulled up or down by 20kOhm resistor to select proper bootstrap configuration.

Default configuration: pull-down (BOOT_MODE[1]=0)
J1.125 SPI0_DQ0/MODE3/NAND_ALE CPU.PS_MIO2_500
NOR flash
NAND flash
CPU.A21 Bank 500 I/O 3.3V This signal is pulled up or down by 20kOhm resistor to select proper bootstrap configuration.

Default configuration: pull-down (BOOT_MODE[3]=0)
J1.127 DGND DGND - - G - Digital ground
J1.129 SPI0_SCLK/MODE4/NAND_IO1 CPU.PS_MIO6_500
NOR flash
NAND flash
CPU.A19 Bank 500 I/O 3.3V This signal is pulled up or down by 20kOhm resistor to select proper bootstrap configuration.

Default configuration: pull-down (BOOT_MODE[4]=0)
J1.131 NAND_BUSY CPU.PS_MIO14_500
NOR flash
NAND flash
CPU.B17 Bank 500 I/O 3.3V 10kOhm pull-up
J1.133 PS_MIO15_500 CPU.PS_MIO15_500
WDT.WDI
CPU.E17
WDT.1
Bank 500 I/O 3.3V See also this page
J1.135 RFU - - - - - Reserved fo future use. Must be left floating.
J1.137 MEM_WPn NAND.WP
NOR.WP/IO2
NAND.19
NOR.C4
3.3V
J1.139 DGND DGND - - G - Digital ground

J1 even pins (2 to 140)[edit | edit source]

Pin Pin Name Internal Connections Ball/pin # Supply Group Type Voltage Note
J1.2 VDDIO_BANK35 S
J1.4 DGND DGND - - - G Digital ground
J1.6 IO_L24P_T3_AD15P_35 FPGA.IO_L24P_T3_AD15P_35 H1 Bank 35 I/O User defined
J1.8 IO_L24N_T3_AD15N_35 FPGA.IO_L24N_T3_AD15N_35 G1 Bank 35 I/O User defined
J1.10 IO_L22P_T3_AD7P_35 FPGA.IO_L22P_T3_AD7P_35 G3 Bank 35 I/O User defined
J1.12 IO_L22N_T3_AD7N_35 FPGA.IO_L22N_T3_AD7N_35 G2 Bank 35 I/O User defined
J1.14 DGND DGND - - - G Digital ground
J1.16 IO_L20P_T3_AD6P_35 FPGA.IO_L20P_T3_AD6P_35 G4 Bank 35 I/O User defined
J1.18 IO_L20N_T3_AD6N_35 FPGA.IO_L20N_T3_AD6N_35 F4 Bank 35 I/O User defined
J1.20 IO_L18P_T2_AD13P_35 FPGA.IO_L20N_T3_AD6N_35 B2 Bank 35 I/O User defined
J1.22 IO_L18N_T2_AD13N_35 FPGA.IO_L18N_T2_AD13N_35 B1 Bank 35 I/O User defined
J1.24 DGND DGND - - - G Digital ground
J1.26 IO_L16P_T2_35 FPGA.IO_L16P_T2_35 D1 Bank 35 I/O User defined
J1.28 IO_L16N_T2_35 FPGA.IO_L16N_T2_35 C1 Bank 35 I/O User defined
J1.30 DGND DGND - - - G Digital ground
J1.32 IO_L14P_T2_AD4P_SRCC_35 FPGA.IO_L14P_T2_AD4P_SRCC_35 D3 Bank 35 I/O User defined
J1.34 IO_L14N_T2_AD4N_SRCC_35 FPGA.IO_L14N_T2_AD4N_SRCC_35 C3 Bank 35 I/O User defined
J1.36 IO_L12P_T1_MRCC_35 FPGA.IO_L12P_T1_MRCC_35 D5 Bank 35 I/O User defined
J1.38 DGND DGND - - - G Digital ground
J1.40 IO_L12N_T1_MRCC_35 FPGA.IO_L12N_T1_MRCC_35 C4 Bank 35 I/O User defined
J1.42 IO_L10P_T1_AD11P_35 FPGA.IO_L10P_T1_AD11P_35 A5 Bank 35 I/O User defined
J1.44 IO_L10N_T1_AD11N_35 FPGA.IO_L10N_T1_AD11N_35 A4 Bank 35 I/O User defined
J1.46 IO_L8P_T1_AD10P_35 FPGA.IO_L8P_T1_AD10P_35 B7 Bank 35 I/O User defined
J1.48 DGND DGND - - - G Digital ground
J1.50 IO_L8N_T1_AD10N_35 FPGA.IO_L8N_T1_AD10N_35 B6 Bank 35 I/O User defined
J1.52 IO_L6P_T0_35 FPGA.IO_L6P_T0_35 G6 Bank 35 I/O User defined
J1.54 IO_L6N_T0_VREF_35 FPGA.IO_L6N_T0_VREF_35 F6 Bank 35 I/O User defined
J1.56 IO_L4P_T0_35 FPGA.IO_L4P_T0_35 G8 Bank 35 I/O User defined
J1.58 IO_L4N_T0_35 FPGA.IO_L4N_T0_35 G7 Bank 35 I/O User defined
J1.60 DGND DGND - - - G Digital ground
J1.62 IO_L2P_T0_AD8P_35 FPGA.IO_L2P_T0_AD8P_35 D7 Bank 35 I/O User defined
J1.64 IO_L2N_T0_AD8N_35 FPGA.IO_L2N_T0_AD8N_35 D6 Bank 35 I/O User defined
J1.66 VDDIO_BANK35 S
J1.68 VDDIO_BANK35 S
J1.70 XADC_AGND G XADC analog ground (internally connected to DGND)
J1.72 XADC_AGND G XADC analog ground (internally connected to DGND)
J1.74 IO_0_VRN_35 FPGA.IO_0_35/IO_0_VRN_35 H6 Bank 35 I/O User defined Optional on-board pull-up
J1.76 RFU - - - - - Reserved fo future use. Must be left floating.
J1.78 RFU - - - - - Reserved fo future use. Must be left floating.
J1.80 PS_MIO49_501 CPU.PS_MIO49_501 C9 Bank 501 I/O 1.8V
J1.82 PS_MIO48_501 CPU.PS_MIO48_501 D12 Bank 501 I/O 1.8V
J1.84 PS_MIO47_501 CPU.PS_MIO47_501 B13 Bank 501 I/O 1.8V 10kOhm pull-up

TBD

J1.86 DGND DGND - - - G Digital ground
J1.88 PS_MIO46_501 CPU.PS_MIO46_501 D11 Bank 501 I/O 1.8V 10kOhm pull-up

TBD

J1.90 ETH_INTn Can be optionally connected to Ethernet PHY's INT_N / PME_N2
J1.92 DGND DGND - - - G Digital ground
J1.94 ETH_TXRX3_M LAN.TXRXM_D 11 D
J1.96 ETH_TXRX3_P LAN.TXRXP_D 10 D
J1.98 DGND DGND - - - G Digital ground
J1.100 ETH_TXRX2_M
J1.102 ETH_TXRX2_P
J1.104 DGND DGND - - - G Digital ground
J1.106 CLK125_NDO LAN.CLK125_NDO 41 O 1.8V 10kOhm pull-up
J1.108 RFU - - - - - Reserved fo future use. Must be left floating.
J1.110 RFU - - - - - Reserved fo future use. Must be left floating.
J1.112 DGND DGND - - - G Digital ground
J1.114 USBP1 USB.DP 6 D
J1.116 USBM1 USB.DM 5 D
J1.118 DGND DGND - - - G Digital ground
J1.120 SPI0_CS0n CPU.PS_MIO1_500
NOR flash
CPU.A22 Bank 500 I/O 3.3V
J1.122 NAND_CS0/SPI0_CS1 CPU.PS_MIO0_500
NAND flash
CPU.G17 Bank 500 I/O 3.3V 10kOhm pull-up
J1.124 NAND_IO3 CPU.PS_MIO13_500
NAND flash
CPU.A17 Bank 500 I/O 3.3V
J1.126 NAND_IO4 CPU.PS_MIO9_500
NAND flash
CPU.C19 Bank 500 I/O 3.3V
J1.128 NAND_IO5 CPU.PS_MIO10_500
NAND flash
CPU.G16 Bank 500 I/O 3.3V
J1.130 DGND DGND - - - G Digital ground
J1.132 NAND_IO6 CPU.PS_MIO11_500
NAND flash
CPU.B19 Bank 500 I/O 3.3V
J1.134 NAND_IO7 CPU.PS_MIO12_500
NAND flash
CPU.C18 Bank 500 I/O 3.3V
J1.136 NAND_RD_B/VCFG1 CPU.PS_MIO8_500
NAND flash
CPU.E18 Bank 500 I/O 3.3V This signal is pulled up or down by 20kOhm resistor to select proper bootstrap configuration.
J1.138 NAND_CLE/VCFG0 CPU.PS_MIO7_500
NAND flash
CPU.D18 Bank 500 I/O 3.3V This signal is pulled up or down by 20kOhm resistor to select proper bootstrap configuration.
J1.140 DGND DGND - - - G Digital ground

J2 odd pins (1 to 139)[edit | edit source]

Pin Pin Name Internal Connections Ball/pin # Supply Group Type Voltage Note
J2.1 DGND DGND - - G - Digital ground
J2.3 DGND DGND - - G - Digital ground
J2.5 IO_L8P_T1_34 FPGA.IO_L8P_T1_34 J2 Bank 34 I/O User defined
J2.7 IO_L8N_T1_34 FPGA.IO_L8N_T1_34 J1 Bank 34 I/O User defined
J2.9 IO_L6P_T0_34 FPGA.IO_L6P_T0_34 M8 Bank 34 I/O User defined CAN_RX
J2.11 IO_L6N_T0_VREF_34 FPGA.IO_L6N_T0_VREF_34 M7 Bank 34 I/O User defined
J2.13 DGND DGND - - G - Digital ground
J2.15 IO_L3P_T0_DQS_PUDC_B_34 FPGA.IO_L3P_T0_DQS_PUDC_B_34 K7 Bank 34 I/O User defined Internally connected to VDDIO_BANK34 via 10K resistor
J2.17 IO_L3N_T0_DQS_34 FPGA.IO_L3N_T0_DQS_34 L7 Bank 34 I/O User defined
J2.19 IO_L2P_T0_34 FPGA.IO_L2P_T0_34 J7 Bank 34 I/O User defined
J2.21 IO_L2N_T0_34 FPGA.IO_L2N_T0_34 J6 Bank 34 I/O User defined
J2.23 DGND DGND - - G - Digital ground
J2.25 IO_L22P_T3_34 FPGA.IO_L22P_T3_34 M4 Bank 34 I/O User defined
J2.27 IO_L22N_T3_34 FPGA.IO_L22N_T3_34 M3 Bank 34 I/O User defined
J2.29 IO_L21P_T3_DQS_34 FPGA.IO_L21P_T3_DQS_34 N4 Bank 34 I/O User defined
J2.31 IO_L21N_T3_DQS_34 FPGA.IO_L21N_T3_DQS_34 N3 Bank 34 I/O User defined
J2.33 DGND DGND - - G - Digital ground
J2.35 IO_L19P_T3_34 FPGA.IO_L19P_T3_34 N6 Bank 34 I/O User defined CAN_TX
J2.37 IO_L19N_T3_VREF_34 FPGA.IO_L19N_T3_VREF_34 N5 Bank 34 I/O User defined
J2.39 IO_L18P_T2_34 FPGA.IO_L18P_T2_34 P3 Bank 34 I/O User defined
J2.41 IO_L18N_T2_34 FPGA.IO_L18N_T2_34 P2 Bank 34 I/O User defined
J2.43 DGND DGND - - G - Digital ground
J2.45 IO_L15P_T2_DQS_34 FPGA.IO_L15P_T2_DQS_34 M2 Bank 34 I/O User defined
J2.47 IO_L15N_T2_DQS_34 FPGA.IO_L15N_T2_DQS_34 M1 Bank 34 I/O User defined
J2.49 DGND DGND - - G - Digital ground
J2.51 IO_L13P_T1_MRCC_34 FPGA.IO_L13P_T1_MRCC_34 T2 Bank 34 I/O User defined
J2.53 IO_L13N_T1_MRCC_34 FPGA.IO_L13N_T1_MRCC_34 T1 Bank 34 I/O User defined
J2.55 DGND DGND - - G - Digital ground
J2.57 IO_L11P_T1_SRCC_34 FPGA.IO_L11P_T1_SRCC_34 K4 Bank 34 I/O User defined
J2.59 IO_L11N_T1_SRCC_34 FPGA.IO_L11N_T1_SRCC_34 K3 Bank 34 I/O User defined
J2.61 DGND DGND - - G - Digital ground
J2.63 IO_L10P_T1_34 FPGA.IO_L10P_T1_34 L2 Bank 34 I/O User defined
J2.65 IO_L10N_T1_34 FPGA.IO_L10N_T1_34 L1 Bank 34 I/O User defined
J2.67 IO_25_VRP_34 FPGA.IO_25_VRP_34 R8 Bank 34 I/O User defined Optional Internal Termination resistors for DCI
J2.69 IO_0_VRN_34 FPGA.IO_0_VRN_34 H8 Bank 34 I/O User defined Optional Internal Termination resistors for DCI
J2.71 DGND DGND - - G - Digital ground
J2.73 RFU - - - - - Reserved for future use. Must be left floating.
J2.75 RFU - - - - - Reserved for future use. Must be left floating.
J2.77 RFU - - - - - Reserved for future use. Must be left floating.
J2.79 RFU - - - - - Reserved for future use. Must be left floating.
J2.81 RFU - - - - - Reserved for future use. Must be left floating.
J2.83 ETH0_PHY_RST LAN.RESET_N 42 BANK 501 O 1.8V Internally connected to DGND via 10K resistor
J2.85 USB0_PHY_RST USB.RESETB 23 BANK 501 O 1.8V Internally connected to DGND via 10K resistor
J2.87 CAN_3STn LEVEL_SHIFTER.3ST# 6 BANK 34 I User defined TBD Internally connected to VDDIO_BANK34 via 10K resistor
J2.89 EXT_VMON2_V1 - - - - Reserved for future use. Must be left floating.
J2.91 EXT_VMON2_V2 - - - - Reserved for future use. Must be left floating.
J2.93 RTC_32KHZ RTC.32KHZ 1 3.3V O 3.3V
J2.95 RTC_RST RTC.~RST 4 3.3V I/O 3.3V
J2.97 XADC_VN_R FPGA.VN_0 L12 Bank 0 A
J2.99 XADC_VP_R FPGA.VP_0 M11 Bank 0 A
J2.101 RFU - - - - - Reserved for future use. Must be left floating.
J2.103 CONN_SPI_RSTn - - - - - Reserved for future use. Must be left floating.
J2.105 CAN_L CAN.CANL 6 - D -
J2.107 CAN_H CAN.CANH 7 - D -
J2.109 DGND DGND - - G - Digital ground
J2.111 RTC_INT/SQW RTC.RTC_INT/SQW 3 3.3V I/O 3.3V It can be left open if not used. When used, a proper pull-up resistor is required on the carrier board. For further details, please refer to the Maxim Integrated DS3232 datasheet.
J2.113 RTC_VBAT RTC.VBAT 6 - S - TBD
J2.115 VBAT CPU.VCCBATT_0 G14 - S - TBD
J2.117 DGND DGND - - G - Digital ground
J2.119 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.121 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.123 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.125 DGND DGND - - G - Digital ground
J2.127 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.129 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.131 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.133 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.135 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.137 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.139 DGND DGND - - G - Digital ground

J2 even pins (2 to 140)[edit | edit source]

Pin Pin Name Internal Connections Ball/pin # Supply Group Type Voltage Note
J2.2 DGND DGND - - G - Digital ground
J2.4 IO_L9P_T1_DQS_34 FPGA.IO_L9P_T1_DQS_34 J3 Bank 34 I/O User defined
J2.6 IO_L9N_T1_DQS_34 FPGA.IO_L9N_T1_DQS_34 K2 Bank 34 I/O User defined
J2.8 IO_L7P_T1_34 FPGA.IO_L7P_T1_34 J5 Bank 34 I/O User defined
J2.10 IO_L7N_T1_34 FPGA.IO_L7N_T1_34 K5 Bank 34 I/O User defined
J2.12 DGND DGND - - G - Digital ground
J2.14 IO_L5P_T0_34 FPGA.IO_L5P_T0_34 N8 Bank 34 I/O User defined
J2.16 IO_L5N_T0_34 FPGA.IO_L5N_T0_34 P8 Bank 34 I/O User defined
J2.18 IO_L4P_T0_34 FPGA.IO_L4P_T0_34 L6 Bank 34 I/O User defined
J2.20 IO_L4N_T0_34 FPGA.IO_L4N_T0_34 M6 Bank 34 I/O User defined
J2.22 DGND DGND - - G - Digital ground
J2.24 IO_L24P_T3_34 FPGA.IO_L24P_T3_34 P7 Bank 34 I/O User defined
J2.26 IO_L24N_T3_34 FPGA.IO_L24N_T3_34 R7 Bank 34 I/O User defined
J2.28 IO_L23P_T3_34 FPGA.IO_L23P_T3_34 R5 Bank 34 I/O User defined
J2.30 IO_L23N_T3_34 FPGA.IO_L23N_T3_34 R4 Bank 34 I/O User defined
J2.32 DGND DGND - - G - Digital ground
J2.34 IO_L20P_T3_34 FPGA.IO_L20P_T3_34 P6 Bank 34 I/O User defined
J2.36 IO_L20N_T3_34 FPGA.IO_L20N_T3_34 P5 Bank 34 I/O User defined
J2.38 IO_L1P_T0_34 FPGA.IO_L1P_T0_34 J8 Bank 34 I/O User defined
J2.40 IO_L1N_T0_34 FPGA.IO_L1N_T0_34 K8 Bank 34 I/O User defined
J2.42 DGND DGND - - G - Digital ground
J2.44 IO_L17P_T2_34 FPGA.IO_L17P_T2_34 R3 Bank 34 I/O User defined
J2.46 IO_L17N_T2_34 FPGA.IO_L17N_T2_34 R2 Bank 34 I/O User defined
J2.48 IO_L16P_T2_34 FPGA.IO_L16P_T2_34 N1 Bank 34 I/O User defined
J2.50 IO_L16N_T2_34 FPGA.IO_L16N_T2_34 P1 Bank 34 I/O User defined
J2.52 DGND DGND - - G - Digital ground
J2.54 IO_L14P_T2_SRCC_34 FPGA.IO_L14P_T2_SRCC_34 U2 Bank 34 I/O User defined
J2.56 IO_L14N_T2_SRCC_34 FPGA.IO_L14N_T2_SRCC_34 U1 Bank 34 I/O User defined
J2.58 DGND DGND - - G - Digital ground
J2.60 IO_L12P_T1_MRCC_34 FPGA.IO_L12P_T1_MRCC_34 L5 Bank 34 I/O User defined
J2.62 IO_L12N_T1_MRCC_34 FPGA.IO_L12N_T1_MRCC_34 L4 Bank 34 I/O User defined
J2.64 DGND DGND - - G - Digital ground
J2.66 VDDIO_BANK34 FPGA.VCCO_34 K6
H2
L3
N7
P4
R1
Bank 34 S User defined Bank34 I/O Power Supply
J2.68 VDDIO_BANK34 FPGA.VCCO_34 K6
H2
L3
N7
P4
R1
Bank 34 S User defined Bank34 I/O Power Supply
J2.70 VDDIO_BANK34 FPGA.VCCO_34 K6
H2
L3
N7
P4
R1
Bank 34 S User defined Bank34 I/O Power Supply
J2.72 VDDIO_BANK34 FPGA.VCCO_34 K6
H2
L3
N7
P4
R1
Bank 34 S User defined Bank34 I/O Power Supply
J2.74 RFU - - - - - Reserved for future use. Must be left floating.
J2.76 RFU - - - - - Reserved for future use. Must be left floating.
J2.78 RFU - - - - - Reserved for future use. Must be left floating.
J2.80 JTAG_TDO CPU.TDO_0 G9 BANK 0 O 3.3V
J2.82 JTAG_TDI CPU.TDI_0 H9 BANK 0 I 3.3V
J2.84 JTAG_TMS CPU.TMS_0 H10 BANK 0 I 3.3V
J2.86 JTAG_TCK CPU.TCK_0 H11 BANK 0 I 3.3V
J2.88 DGND DGND - - G - Digital ground
J2.90 FPGA_INIT_B FPGA.INIT_B_0 T8 BANK 0 I/O 3.3V Place external 4.7 kΩ (or stronger) pull-up resistor to BOARD_PGOOD driven +3.3V supply

For more details please refer to Table 2-4 on 7 Series FPGAs Configuration

J2.92 FPGA_PROGRAM_B FPGA.PROGRAM_B_0 V10 BANK 0 I 3.3V Place external 4.7 kΩ (or stronger) pull-up resistor to BOARD_PGOOD driven +3.3V supply

For more details please refer to Table 2-4 on 7 Series FPGAs Configuration

(10 kΩ pull-up resistor is already mounted on BORAX module)

J2.94 FPGA_DONE FPGA.DONE0 T10 BANK 0 I/O 3.3V Place external 300Ω pull-up resistor to BOARD_PGOOD driven +3.3V supply

For more details please refer to Table 2-4 on 7 Series FPGAs Configuration

J2.96 WD_SET2 WDT.SET2 6 3.3V I 3.3V
J2.98 WD_SET1 WDT.SET1 5 3.3V I 3.3V
J2.100 WD_SET0 WDT.SET0 4 3.3V I 3.3V
J2.102 DGND DGND - - G - Digital ground
J2.104 PS_MIO50_501 CPU.PS_MIO50_501
USBOTG.RESETB
D10
22
BANK 501 I/O 1.8V For further details, please refer to Reset_scheme_(BoraXpress)#PS_MIO50_501
J2.106 PS_MIO51_501 CPU.PS_MIO51_501
ETHPHY1GB.RESET_N
C13
42
BANK 501 I/O 1.8V For further details, please refer to Reset_scheme_(BoraXpress)#PS_MIO51_501
J2.108 SOM_PGOOD SOM_PGOOD_LOGIC.OUT n.a. 3.3V O 3.3V Internally connected to DGND via 100K resistor
J2.110 CB_PWR_GOOD 1.0VREGULATOR.ENABLE
SOM_PGOOD_LOGIC.IN
n.a. 3.3VIN I 3.3V Internally connected to 3.3VIN via 10K resistor
J2.112 SYS_RSTn CPU.PS_SRST_B_501 C14 BANK 501 I 1.8V Internally connected to 1.8V via 20K resistor
J2.114 PORSTn CPU.PS_POR_B_500
WD.~WDO
NOR.~RESET/RFU
B18
7
A4
BANK 500 I/O 3.3V Internally connected to 3.3VIN via 2.2K resistor.
For further details, please refer to Reset_scheme_(BoraXpress)#PORSTn
J2.116 MRSTn Voltage monitor 6 3.3VIN I 3.3V Internally connected to 3.3VIN via 2.2K resistor

For further details, please refer to Reset_scheme_(BoraXpress)

J2.118 DGND DGND - - G - Digital ground
J2.120 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.122 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.124 DGND DGND - - G - Digital ground
J2.126 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.128 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.130 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.132 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.134 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.136 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.138 3.3VIN 3.3VIN - 3.3VIN S SOM Power Supply
J2.140 DGND DGND - - G - Digital ground

J3 odd pins (1 to 139)[edit | edit source]

Pin Pin Name Internal Connections Ball/pin # Supply Group Type Voltage Note
J3.1 DGND DGND - - G - Digital ground
J3.3 MGTREFCLK0N FPGA.MGTREFCLK0N_112 V9 MGTAVCC D
J3.5 MGTREFCLK0P FPGA.MGTREFCLK0P_112 U9 MGTAVCC D
J3.7 DGND DGND - - G - Digital ground
J3.9 MGTxTXP0 FPGA.MGTXTXP0_112 AA3 MGTAVCC D
J3.11 MGTxTXN0 FPGA.MGTXTXN0_112 AB3 MGTAVCC D
J3.13 DGND DGND - - G - Digital ground
J3.15 MGTxTXP1 FPGA.MGTXTXP1_112 W4 MGTAVCC D
J3.17 MGTxTXN1 FPGA.MGTXTXN1_112 Y4 MGTAVCC D
J3.19 DGND DGND - - G - Digital ground
J3.21 MGTxTXP2 FPGA.MGTXTXP2_112 AA5 MGTAVCC D
J3.23 MGTxTXN2 FPGA.MGTXTXN2_112 AB5 MGTAVCC D
J3.25 DGND DGND - - G - Digital ground
J3.27 MGTxTXP3 FPGA.MGTXTXP3_112 W2 MGTAVCC D
J3.29 MGTxTXN3 FPGA.MGTXTXN3_112 Y2 MGTAVCC D
J3.31 DGND DGND - - G - Digital ground
J3.33 RFU - - - - - Reserved for future use. Must be left floating.
J3.35 RFU - - - - - Reserved for future use. Must be left floating.
J3.37 DGND DGND - - G - Digital ground
J3.39 IO_L23P_T3_13 FPGA.IO_L23P_T3_13 V16 Bank 13 I/O User defined
J3.41 IO_L23N_T3_13 FPGA.IO_L23N_T3_13 W16 Bank 13 I/O User defined
J3.43 DGND DGND - - G - Digital ground
J3.45 IO_L9P_T1_DQS_13 FPGA.IO_L9P_T1_DQS_13 AB13 Bank 13 I/O User defined
J3.47 IO_L9N_T1_DQS_13 FPGA.IO_L9N_T1_DQS_13 AB14 Bank 13 I/O User defined
J3.49 DGND DGND - - G - Digital ground
J3.51 IO_L7P_T1_13 FPGA.IO_L7P_T1_13 AA11 Bank 13 I/O User defined
J3.53 IO_L7N_T1_13 FPGA.IO_L7N_T1_13 AB11 Bank 13 I/O User defined
J3.55 DGND DGND - - G - Digital ground
J3.57 IO_L5P_T0_13 FPGA.IO_L5P_T0_13 U11 Bank 13 I/O User defined
J3.59 IO_L5N_T0_13 FPGA.IO_L5N_T0_13 U12 Bank 13 I/O User defined
J3.61 DGND DGND - - G - Digital ground
J3.63 IO_L4P_T0_13 FPGA.IO_L4P_T0_13 V11 Bank 13 I/O User defined
J3.65 IO_L4N_T0_13 FPGA.IO_L4N_T0_13 W11 Bank 13 I/O User defined
J3.67 DGND DGND - - G - Digital ground
J3.69 DGND DGND - - G - Digital ground
J3.71 IO_L3P_T0_DQS_13 FPGA.IO_L3P_T0_DQS_13 W12 Bank 13 I/O User defined
J3.73 IO_L3N_T0_DQS_13 FPGA.IO_L3N_T0_DQS_13 W13 Bank 13 I/O User defined
J3.75 DGND DGND - - G - Digital ground
J3.77 IO_L2P_T0_13 FPGA.IO_L2P_T0_13 V15 Bank 13 I/O User defined
J3.79 IO_L2N_T0_13 FPGA.IO_L2N_T0_13 W15 Bank 13 I/O User defined
J3.81 DGND DGND - - G - Digital ground
J3.83 IO_L1P_T0_13 FPGA.IO_L1P_T0_13 V13 Bank 13 I/O User defined
J3.85 IO_L1N_T0_13 FPGA.IO_L1N_T0_13 V14 Bank 13 I/O User defined
J3.87 DGND DGND - - G - Digital ground
J3.89 IO_25_13 FPGA.IO_25_13 U16 Bank 13 I/O User defined
J3.91 IO_0_13 FPGA.IO_0_13 T16 Bank 13 I/O User defined
J3.93 DGND DGND - - G - Digital ground
J3.95 VDDIO_BANK13 FPGA.VCCO_13 AA13
AB20
T18
Y16
W19
V12
U15
Bank 13 S User defined Bank13 I/O Power Supply
J3.97 VDDIO_BANK13 FPGA.VCCO_13 AA13
AB20
T18
Y16
W19
V12
U15
Bank 13 S User defined Bank13 I/O Power Supply
J3.99 VDDIO_BANK13 FPGA.VCCO_13 AA13
AB20
T18
Y16
W19
V12
U15
Bank 13 S User defined Bank13 I/O Power Supply
J3.101 DGND DGND - - G - Digital ground
J3.103 DGND DGND - - G - Digital ground
J3.105 IO_L21P_T3_DQS_13 FPGA.IO_L21P_T3_DQS_13 V18 Bank 13 I/O User defined
J3.107 IO_L21N_T3_DQS_13 FPGA.IO_L21N_T3_DQS_13 W18 Bank 13 I/O User defined
J3.109 DGND DGND - - G - Digital ground
J3.111 IO_L19P_T3_13 FPGA.IO_L19P_T3_13 R17 Bank 13 I/O User defined
J3.113 IO_L19N_T3_VREF_13 FPGA.IO_L19N_T3_VREF_13 T17 Bank 13 I/O User defined
J3.115 DGND DGND - - G - Digital ground
J3.117 IO_L18P_T2_13 FPGA.IO_L18P_T2_13 AA19 Bank 13 I/O User defined
J3.119 IO_L18N_T2_13 FPGA.IO_L18N_T2_13 AA20 Bank 13 I/O User defined
J3.121 DGND DGND - - G - Digital ground
J3.123 IO_L16P_T2_13 FPGA.IO_L16P_T2_13 AB18 Bank 13 I/O User defined
J3.125 IO_L16N_T2_13 FPGA.IO_L16N_T2_13 AB19 Bank 13 I/O User defined
J3.127 DGND DGND - - G - Digital ground
J3.129 IO_L14P_T2_SRCC_13 FPGA.IO_L14P_T2_SRCC_13 AA16 Bank 13 I/O User defined
J3.131 IO_L14N_T2_SRCC_13 FPGA.IO_L14N_T2_SRCC_13 AA17 Bank 13 I/O User defined
J3.133 DGND DGND - - G - Digital ground
J3.135 IO_L12P_T1_MRCC_13 FPGA.IO_L12P_T1_MRCC_13 Y14 Bank 13 I/O User defined
J3.137 IO_L12N_T1_MRCC_13 FPGA.IO_L12N_T1_MRCC_13 Y15 Bank 13 I/O User defined
J3.139 DGND DGND - - G - Digital ground

J3 even pins (2 to 140)[edit | edit source]

Pin Pin Name Internal Connections Ball/pin # Supply Group Type Voltage Note
J3.2 DGND DGND - - G - Digital ground
J3.4 DGND DGND - - G - Digital ground
J3.6 MGTREFCLK1N FPGA.MGTREFCLK1N_112 V5 MGTAVCC D
J3.8 MGTREFCLK1P FPGA.MGTREFCLK1P_112 U5 MGTAVCC D
J3.10 DGND DGND - - G - Digital ground
J3.12 MGTxRXP0 FPGA.MGTXRXP0_112 AA7 MGTAVCC D
J3.14 MGTxRXN0 FPGA.MGTXRXN0_112 AB7 MGTAVCC D
J3.16 DGND DGND - - G - Digital ground
J3.18 MGTxRXP1 FPGA.MGTXRXP1_112 W8 MGTAVCC D
J3.20 MGTxRXN1 FPGA.MGTXRXN1_112 Y8 MGTAVCC D
J3.22 DGND DGND - - G - Digital ground
J3.24 MGTxRXP2 FPGA.MGTXRXP2_112 AA9 MGTAVCC D
J3.26 MGTxRXN2 FPGA.MGTXRXN2_112 AB9 MGTAVCC D
J3.28 DGND DGND - - G - Digital ground
J3.30 MGTxRXP3 FPGA.MGTXRXP3_112 W6 MGTAVCC D
J3.32 MGTxRXN3 FPGA.MGTXRXN3_112 Y6 MGTAVCC D
J3.34 DGND DGND - - G - Digital ground
J3.36 DGND DGND - - G - Digital ground
J3.38 IO_L24P_T3_13 FPGA.IO_L24P_T3_13 W17 Bank 13 I/O User defined
J3.40 IO_L24N_T3_13 FPGA.IO_L24N_T3_13 Y17 Bank 13 I/O User defined
J3.42 DGND DGND - - G - Digital ground
J3.44 IO_L10P_T1_13 FPGA.IO_L10P_T1_13 Y12 Bank 13 I/O User defined
J3.46 IO_L10N_T1_13 FPGA.IO_L10N_T1_13 Y13 Bank 13 I/O User defined
J3.48 DGND DGND - - G - Digital ground
J3.50 IO_L8P_T1_13 FPGA.IO_L8P_T1_13 AA12 Bank 13 I/O User defined
J3.52 IO_L8N_T1_13 FPGA.IO_L8N_T1_13 AB12 Bank 13 I/O User defined
J3.54 DGND DGND - - G - Digital ground
J3.56 IO_L6P_T0_13 FPGA.IO_L6P_T0_13 U13 Bank 13 I/O User defined
J3.58 IO_L6N_T0_VREF_13 FPGA.IO_L6N_T0_VREF_13 U14 Bank 13 I/O User defined
J3.60 DGND DGND - - G - Digital ground
J3.62 MON_MGTAVCC A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.64 MON_MGTAVCCAUX A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.66 MON_MGTAVTT A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.68 DGND DGND - - G - Digital ground
J3.70 RFU - - - - - Reserved for future use. Must be left floating.
J3.72 MON_VCCPLL A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.74 MON_XADC_VCC A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.76 MON_FPGA_VDDIO_BANK35 A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.78 MON_FPGA_VDDIO_BANK34 A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.80 MON_FPGA_VDDIO_BANK13 A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.82 MON_1.8V_IO A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.84 MON_3.3V A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.86 MON_1V2_ETH A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.88 MON_VDDQ_1V5 A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.90 MON_1.8V A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.92 MON_1.0V A By default this pin must not be connected. Optionally it can route power voltage generated by BoraXpress PSU. This option is meant to allow monitoring such voltage by carrier board circuitry. It is not meant to power carrier board devices. For more information please contact technical support.
J3.94 DGND DGND - - G - Digital ground
J3.96 VDDIO_BANK13 FPGA.VCCO_13 AA13
AB20
T18
Y16
W19
V12
U15
Bank 13 S User defined Bank13 I/O Power Supply
J3.98 VDDIO_BANK13 FPGA.VCCO_13 AA13
AB20
T18
Y16
W19
V12
U15
Bank 13 S User defined Bank13 I/O Power Supply
J3.100 RFU - - - - - Reserved for future use. Must be left floating.
J3.102 DGND DGND - - G - Digital ground
J3.104 IO_L22P_T3_13 FPGA.IO_L22P_T3_13 U17 Bank 13 I/O User defined
J3.106 IO_L22N_T3_13 FPGA.IO_L22N_T3_13 U18 Bank 13 I/O User defined
J3.108 DGND DGND - - G - Digital ground
J3.110 IO_L20P_T3_13 FPGA.IO_L20P_T3_13 U19 Bank 13 I/O User defined
J3.112 IO_L20N_T3_13 FPGA.IO_L20N_T3_13 V19 Bank 13 I/O User defined
J3.114 DGND DGND - - G - Digital ground
J3.116 IO_L17P_T2_13 FPGA.IO_L17P_T2_13 AB16 Bank 13 I/O User defined
J3.118 IO_L17N_T2_13 FPGA.IO_L17N_T2_13 AB17 Bank 13 I/O User defined
J3.120 DGND DGND - - G - Digital ground
J3.122 IO_L15P_T2_DQS_13 FPGA.IO_L15P_T2_DQS_13 AB21 Bank 13 I/O User defined
J3.124 IO_L15N_T2_DQS_13 FPGA.IO_L15N_T2_DQS_13 AB22 Bank 13 I/O User defined
J3.126 DGND DGND - - G - Digital ground
J3.128 IO_L13P_T2_MRCC_13 FPGA.IO_L13P_T2_MRCC_13 Y18 Bank 13 I/O User defined
J3.130 IO_L13N_T2_MRCC_13 FPGA.IO_L13N_T2_MRCC_13 Y19 Bank 13 I/O User defined
J3.132 DGND DGND - - G - Digital ground
J3.134 IO_L11P_T1_SRCC_13 FPGA.IO_L11P_T1_SRCC_13 AA14 Bank 13 I/O User defined
J3.136 IO_L11N_T1_SRCC_13 FPGA.IO_L11N_T1_SRCC_13 AA15 Bank 13 I/O User defined
J3.138 DGND DGND - - G - Digital ground
J3.140 DGND DGND - - G - Digital ground