Changes

Jump to: navigation, search
Future work
For these reasons, [https://www.nxp.com/products/processors-and-microcontrollers/arm-processors/i-mx-applications-processors/i-mx-8-processors/i-mx-8m-plus-arm-cortex-a53-machine-learning-vision-multimedia-and-industrial-iot:IMX8MPLUS NXP i.MX8M Plus] will be one of the key components considered for the possible product industrialization, as DAVE Embedded Systems is part of the beta program associated with this system-on-chip.
 
== Appendix A ==
In this appendix, the
<pre class="board-terminal">
[2020-08-10 10:48:53,674][INFO][main_logger.main] SAVING_ALARM_BUFFER -> STREAM_ONLY
[2020-08-10 10:48:53,675][INFO][main_logger.main] STREAM_ONLY -> WAITING_FOR_ALARM
[2020-08-10 10:49:22,570][DEBUG][main_logger.main] Alarm signal asserted
[2020-08-10 10:49:22,571][INFO][main_logger.main] WAITING_FOR_ALARM -> FILLING_ALARM_BUFFER
[2020-08-10 10:49:23,571][DEBUG][main_logger.main] Alarm signal deasserted
[2020-08-10 10:49:25,631][INFO][main_logger.alarmbuffersaverthread] Starting AlarmBufferSaverThread ...
[2020-08-10 10:49:25,631][INFO][main_logger.main] FILLING_ALARM_BUFFER -> SAVING_ALARM_BUFFER
[2020-08-10 10:49:25,678][ERROR][main_logger.main] Abnormal frame rate (42.6 fps)
[2020-08-10 10:49:25,716][INFO][main_logger.alarmbuffersaverthread] Deleting oldest alarm ...
[2020-08-10 10:49:25,778][ERROR][main_logger.main] Abnormal frame rate (59.6 fps)
[2020-08-10 10:49:25,839][ERROR][main_logger.main] Abnormal frame rate (74.5 fps)
[2020-08-10 10:49:25,938][INFO][main_logger.alarmbuffersaverthread] Saving to /mnt/alarms/2020-08-10_10.49.22_CEST
[2020-08-10 10:50:45,750][ERROR][main_logger.main] Stopping to stream frames ...
[2020-08-10 10:50:45,784][ERROR][main_logger.main] It is enough data for buffer ...
[2020-08-10 10:50:48,822][ERROR][main_logger.main] Stopping to stream frames ...
[2020-08-10 10:50:48,855][ERROR][main_logger.main] It is enough data for buffer ...
[2020-08-10 10:51:02,582][DEBUG][main_logger.main] Alarm signal asserted
[2020-08-10 10:51:03,581][DEBUG][main_logger.main] Alarm signal deasserted
[2020-08-10 10:51:59,825][INFO][main_logger.alarmbuffersaverthread] Ending AlarmBufferSaverThread ...
[2020-08-10 10:51:59,844][INFO][main_logger.main] SAVING_ALARM_BUFFER -> STREAM_ONLY
[2020-08-10 10:51:59,844][INFO][main_logger.main] STREAM_ONLY -> WAITING_FOR_ALARM
</pre>
 
== Appendix B ==
MISC-TN-015-timer-alarm-signal.png
 
MISC-TN-015-timer-refresh-alarm.png
==Credits==
*Industrial automation image source: [https://www.freepik.com/vectors/technology Technology vector created by macrovector - www.freepik.com]
4,650
edits

Navigation menu