Known limitations
== Known limitations ==
The following table reports the known limitations of the latest version of the carrier board:
 
{| class="wikitable"
|-
!Issue
!Description
|-
| ETH0 interface
| Mistake in the connection of the center tap pins. They should be separated from one another and connected through separate 0.1μF common-mode capacitors to ground (for further details (eg: connection and selection of the magnetics), please refer to the Micrel KSZ9031RNX datasheet).
|-
|}