Open main menu

DAVE Developer's Wiki β

Changes

Additional industrial I/Os (XUAL)

1,561 bytes added, 10:27, 15 November 2016
Created page with "{{InfoBoxTop}} {{AppliesToSBCLynx}} {{AppliesToAddOnSBCLynx}} {{InfoBoxBottom}} __FORCETOC__ ==Additional industrial I/Os (XUAL)== This add-on examples how to add an isolate..."
{{InfoBoxTop}}
{{AppliesToSBCLynx}}
{{AppliesToAddOnSBCLynx}}
{{InfoBoxBottom}}

__FORCETOC__

==Additional industrial I/Os (XUAL)==
This add-on examples how to add an isolated relay, digital isolated I/Os and an ADC interfaces to the SBC Lynx.

[[File:SBCLYNX_ADDON_XUAL.JPG|400px|frameless|border]]

The Add-on fits on J53 and J54 connectors, but uses signals and powers from J54 connector only.

[[File:SBCLYNX_ADDON_XUAL Mounted.JPG|400px|frameless|border]]

=== Technical Specifications ===
{| class="wikitable"
|+Technical Specifications
|-
|'''Feature'''
|'''Description'''
|'''Ports'''
|-
| PT100 ADC PORT||ADC Interface for PT100 Probe||1
|-
| Isolated Relay Output||Common Input Dual Relay Output||2
|-
| Digital Input||12-24V Input Digital I/O 2KV Isolated||2
|-
|}

=== Pinout ===
{| class="wikitable"
|+Pinout
|-
|'''Connector'''
|'''PIN'''
|'''Pin Name'''
|'''Description or Usage'''
|-
| J54||1||VIN||Power IN (from SBC Lynx VIN)
|-
| J54||2||PMIC_5V||Relay coil PSU
|-
| J54||3||3V3_AUX||Internal PSU
|-
| J54||4||VDDA_ADC_3P3||ADC reference voltage
|-
| J54||5||ADC_IN||ADC Input for uC
|-
| J54||6||DOUT_0||Relay 0 coil activation
|-
| J54||7||DOUT_1||Relay1 coil activation
|-
| J54||8||DIN_0||Digital Input 0
|-
| J54||9||DIN_1||Digital Input 1
|-
| J54||10||GND||System GND
|-
| J53||1||NC||
|-
| J53||2||NC||
|-
| J53||3||NC||
|-
| J53||4||NC||
|-
| J53||5||NC||
|-
| J53||6||NC||
|-
| J53||7||NC||
|-
| J53||8||NC||
|-
| J53||9||NC||
|-
| J53||10||NC||
|-
|}

=== Compatibility list ===
SBC Lynx that supports this add-ons:
* S-XUBxx3xxxR